Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.336
Filtrar
1.
HNO ; 2024 Apr 09.
Artigo em Alemão | MEDLINE | ID: mdl-38592481

RESUMO

BACKGROUND: Results of neurotological function diagnostics in the context of interdisciplinary vertigo assessment are usually formulated as free-text reports (FTR). These are often subject to high variability, which may lead to loss of information. The aim of the present study was to evaluate the completeness of structured reports (SR) and referrer satisfaction in the neurotological assessment of vertigo. MATERIALS AND METHODS: Neurotological function diagnostics performed as referrals (n = 88) were evaluated retrospectively. On the basis of the available raw data, SRs corresponding to FTRs from clinical routine were created by means of a specific SR template for neurotological function diagnostics. FTRs and SRs were evaluated for completeness and referring physician satisfaction (n = 8) using a visual analog scale (VAS) questionnaire. RESULTS: Compared to FTRs, SRs showed significantly increased overall completeness (73.7% vs. 51.7%, p < 0.001), especially in terms of patient history (92.5% vs. 66.7%, p < 0.001), description of previous findings (87.5% vs. 38%, p < 0.001), and neurotological (33.5% vs. 26.7%, p < 0.001) and audiometric function diagnostics (58% vs. 32.3%, p < 0.001). In addition, SR showed significantly increased referring physician satisfaction (VAS 8.8 vs. 4.9, p < 0.001). CONCLUSION: Neurotological SRs enable a significantly increased report completeness with higher referrer satisfaction in the context of interdisciplinary assessment of vertigo. Furthermore, SRs are particularly suitable for scientific data analysis, especially in the context of big data analyses.

2.
Indian J Otolaryngol Head Neck Surg ; 76(2): 1711-1715, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38566725

RESUMO

Aim: Anaemia is a prevalent medical condition that impacts a significant proportion of the worldwide populace. While the cardiovascular and respiratory systems' influence on anaemia has been extensively researched, its effect on the auditory system remains unclear. The objective of this investigation was to assess the pure tone audiometry of individuals with anaemia and establish a connection between the type of hearing impairment and the level of anaemia, if any. Materials and Methods: This cross-sectional study comprised 100 patients who were diagnosed with anaemia. All study participants underwent a thorough general examination and hearing assessment, which encompassed tuning fork tests, and pure-tone audiometry. Statistical analysis was utilized to determine the type and severity of hearing loss and its correlation with the degree of anaemia. Results: Our research findings indicate that 46.8% of moderately anaemic patients and 62.9% of patients with severe anaemia exhibited sensorineural hearing loss. A significant correlation was observed between the degree of anaemia (p < 0.05) and hearing loss. Our research findings indicate that individuals with moderate and severe anaemia exhibit a notably greater incidence of hearing impairment in comparison to those with mild anaemia. Conclusion: The research findings thus suggest a potential correlation between anaemia and auditory impairment. The timely identification and management of anaemia could potentially play a crucial role in preventing or reducing hearing impairment among individuals with anaemia. Additional research is required to clarify the mechanisms that underlie this association and to investigate possible interventions for mitigating the risk of hearing impairment in individuals with anaemia.

3.
J Family Med Prim Care ; 13(2): 517-523, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38605746

RESUMO

Introduction: Hearing loss is a global issue of hearing disability and early detection and rehabilitation of hearing loss are important for the development of speech and language skills in hearing-impaired infants. There are multiple risk factors that aid in hearing loss but some are potential factors that contribute toward hearing loss in infants. The aim of this study was to assess the burden of hearing loss and its correlation with risk factors among high-risk infants at a teaching institution in Jaipur, Rajasthan. Method: This study was carried out after approval of institutional ethics committee on a total of 320 high-risk infants at RUHS College of medical sciences and associated hospitals. Hearing loss was assessed by brainstem evoked response audiometry (BERA). Statistical analysis of data was done by cross-tabulation analysis with Pearson correlation and quantile regression. Results: Out of 320 high-risk infants, 59.69% of infants had normal hearing, 9.09% Unilaterally hearing impaired, 20.31% were bilaterally mild-moderate hearing loss, and 10.94% had severe-profound deafness. The prevalence of important risk factors viz. hyperbilirubinemia, low birth weight, appearance, pulse, grimace, activity, and respiration score, meconium aspiration, respiratory distress, and ventilation greater than five days were 86%, 58.9%, 40%, 36%, 29%, and 22%, respectively. Conclusion: In high-risk infants, hearing loss is a common hearing disorder. Because of this, early diagnosis of hearing loss gives them the best chance of developing functional speech. Brainstem evoked response audiometry is a simple, reliable, and effective technique for the assessment of auditory functions in infants.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38642086

RESUMO

PURPOSE: The definitive treatment for chronic suppurative otitis media is surgery. Surgical technique and procedure varies according to individual case findings and pathology and may require mastoidectomies in which the canal wall is preserved or lowered to eradicate disease from mastoid air cells. Surgical treatment of chronic middle ear disease carries a risk of damage to the inner ear. The aim of this study was to investigate whether the noise produced by the tour system following chronic ear surgery causes sensorineural hearing loss, a condition for which not many studies have been published in the literature. METHODS: The study consisted of a total of 49 patients with type I, type II and type III canal wall preservation and 62 patients with tympanoplasty with canal wall preservation and lowering. Bone and air thresholds were compared before and after middle ear surgery. Changes in bone and air thresholds were compared according to the type of tympanoplasty. RESULTS: In the ICW-I, ICW-II and ICW-III tympanoplasties, and in the ICW and CWD tympanoplasties, the preoperative and postoperative values of the opposite ear hearing measurements were performed, and did not differ according to the type of surgery. There is no correlation drilling duration and hearing for the opposite ear. CONCLUSION: The prevention of postoperative sensorineural hearing loss depends on multiple factors, and assessing the magnitude of hearing loss in relation to these factors is important in determining the success of the surgery.

5.
Med Devices (Auckl) ; 17: 151-163, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38659994

RESUMO

The popularity of mobile devices, combined with advances in electronic design and internet technology, has enabled home-based hearing tests in recent years. The purpose of this article is to highlight the distinctive aspects of pure-tone audiometry performed on a mobile device by means of the Hearing Test app for Android devices. The first version of this app was released a decade ago, and since then the app has been systematically improved, which required addressing many issues common to the majority of mobile apps for hearing testing. The article discusses techniques for mobile device calibration, outlines the testing procedure and how it differs from traditional pure-tone audiometry, explores the potential for bone conduction testing, and provides considerations for interpreting mobile audiometry including test duration and background noise. The article concludes by detailing clinically relevant aspects requiring special attention during testing and interpretation of results which are of substantial value to the hundreds of thousands of active users of the Hearing Test app worldwide, as well as to users of other hearing test apps.

6.
Acta Otolaryngol ; : 1-12, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38648394

RESUMO

BACKGROUND: The indication criteria for cochlear implantation differ considerably across regions. OBJECTIVES: To estimate the effects of different candidacy criteria on the number of cochlear implant (CI) candidates. METHODS: We analysed a very large clinical audiological database comprising pure-tone thresholds and speech-audiometric data in order to identify CI candidates on the basis of different audiometric candidacy criteria. In particular, we simulated the effects of three different CI candidacy criteria. RESULTS: The bilateral evaluation of CI candidacy has the strongest influence on the number of potential CI candidates. Additionally, the cut-off criteria for middle-ear implants have a large effect on numbers of candidates when air conduction has deteriorated.Conclusions and Significance: Expanding the indication criteria opens up the possibility of improving the accurate identification of individual cases suitable for cochlear-implant provision.

7.
Am J Clin Nutr ; 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38447686

RESUMO

BACKGROUND: Hearing loss, a public health issue in older populations, is closely related to functional decline. OBJECTIVE: To investigate the longitudinal associations between 4 dietary indices and hearing status. METHODS: Data from the Baltimore Longitudinal Study of Aging were used and included 882 participants ≥45 y of age. Dietary intake was assessed using a validated food frequency questionnaire, and 4 dietary scores (Mediterranean-Dietary Approaches to Stop Hypertension Intervention for Neurodegenerative Delay diet [MIND], Mediterranean style diet score [MDS], Alternative Healthy Eating Index [AHEI], and Healthy Eating Index [HEI]) were calculated as averages over time. Hearing status was examined using pure-tone audiometry, and pure-tone average (PTA) of hearing thresholds were calculated at speech-level (PTA(500, 1000, 2000, 4000 Hz)), low (PTA(500, 1000 Hz)), and high (PTA(4000, 8000 Hz)) frequencies, with lower thresholds indicating better hearing. Multivariable linear mixed-effect models were used to examine associations between dietary indices and hearing threshold change over time adjusted for confounders. RESULTS: At baseline, the mean age of participants was 67 y and 55% were female. Over a median of 8 y of follow-up, MDS ≥7 was associated with 3.5 (95% CI: -6.5, -0.4) and 5.0 (95% CI: -9.1, -1.0) dB lower PTA(500, 1000, 2000, 4000 Hz) and PTA(4000, 8000 Hz), respectively, compared with MDS ≤3; the highest tertile of the AHEI was associated with 2.3 (95% CI: -4.6, -0.1) and 5.0 (95% CI: -8.0, -2.0) dB lower PTA(500, 1000, 2000, 4000 Hz) and PTA(4000, 8000 Hz); and each standard deviation increment in HEI was associated with 1.6 dB (95% CI: -2.7, -0.6), 1.1 dB (95% CI: -2.1, -0.1), and 2.1 dB (95% CI: -3.5, -0.6) lower PTA(500, 1000, 2000, 4000 Hz), PTA(500, 1000 Hz), and PTA(4000, 8000 Hz), respectively. CONCLUSIONS: Adherence to healthy dietary patterns was associated with better hearing status, with stronger associations at high frequencies. Am J Clin Nutr 20xx;x:xx.

8.
Br J Haematol ; 2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38500389

RESUMO

BACKGROUND: Despite numerous studies, the true scenario of hearing loss in beta-thalassaemia remains rather nebulous. MATERIALS AND METHODS: Pure tone audiometry, chelation therapy, demographics and laboratory data of 376 patients (mean age 38.5 ± 16.6 years, 204 females, 66 non-transfusion-dependent) and 139 healthy controls (mean age 37.6 ± 17.7 years, 81 females) were collected. RESULTS: Patient and control groups did not differ for age (p = 0.59) or sex (p = 0.44). Hypoacusis rate was higher in patients (26.6% vs. 7.2%; p < 0.00001), correlated with male sex (32.6% in males vs. 21.8% in females; p = 0.01) and it was sensorineural in 79/100. Hypoacusis rate correlated with increasing age (p = 0.0006) but not with phenotype (13/66 non-transfusion-dependent vs. 87/310 transfusion-dependent patients; p = 0.16). Sensorineural-notch prevalence rate did not differ between patients (11.4%) and controls (12.2%); it correlated with age (p = 0.01) but not with patients' sex or phenotype. Among adult patients without chelation therapy, the sensorineural hypoacusis rate was non-significantly lower compared to chelation-treated patients while it was significantly higher compared to controls (p = 0.003). CONCLUSIONS: Sensorineural hypoacusis rate is high in beta-thalassaemia (about 21%) and it increases with age and in males while disease severity or chelation treatment seems to be less relevant. The meaning of sensorineural-notch in beta-thalassaemia appears questionable.

9.
Front Digit Health ; 6: 1267799, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38532831

RESUMO

Computational audiology (CA) has grown over the last few years with the improvement of computing power and the growth of machine learning (ML) models. There are today several audiogram databases which have been used to improve the accuracy of CA models as well as reduce testing time and diagnostic complexity. However, these CA models have mainly been trained on single populations. This study integrated contextual and prior knowledge from audiogram databases of multiple populations as informative priors to estimate audiograms more precisely using two mechanisms: (1) a mapping function drawn from feature-based homogeneous Transfer Learning (TL) also known as Domain Adaptation (DA) and (2) Active Learning (Uncertainty Sampling) using a stream-based query mechanism. Simulations of the Active Transfer Learning (ATL) model were tested against a traditional adaptive staircase method akin to the Hughson-Westlake (HW) method for the left ear at frequencies ω=0.25,0.5,1,2,4,8 kHz, resulting in accuracy and reliability improvements. ATL improved HW tests from a mean of 41.3 sound stimuli presentations and reliability of ±9.02 dB down to 25.3±1.04 dB. Integrating multiple databases also resulted in classifying the audiograms into 18 phenotypes, which means that with increasing data-driven CA, higher precision is achievable, and a possible re-conceptualisation of the notion of phenotype classifications might be required. The study contributes to CA in identifying an ATL mechanism to leverage existing audiogram databases and CA models across different population groups. Further studies can be done for other psychophysical phenomena using ATL.

10.
Trends Hear ; 28: 23312165241229057, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38483979

RESUMO

A practical speech audiometry tool is the digits-in-noise (DIN) test for hearing screening of populations of varying ages and hearing status. The test is usually conducted by a human supervisor (e.g., clinician), who scores the responses spoken by the listener, or online, where software scores the responses entered by the listener. The test has 24-digit triplets presented in an adaptive staircase procedure, resulting in a speech reception threshold (SRT). We propose an alternative automated DIN test setup that can evaluate spoken responses whilst conducted without a human supervisor, using the open-source automatic speech recognition toolkit, Kaldi-NL. Thirty self-reported normal-hearing Dutch adults (19-64 years) completed one DIN + Kaldi-NL test. Their spoken responses were recorded and used for evaluating the transcript of decoded responses by Kaldi-NL. Study 1 evaluated the Kaldi-NL performance through its word error rate (WER), percentage of summed decoding errors regarding only digits found in the transcript compared to the total number of digits present in the spoken responses. Average WER across participants was 5.0% (range 0-48%, SD = 8.8%), with average decoding errors in three triplets per participant. Study 2 analyzed the effect that triplets with decoding errors from Kaldi-NL had on the DIN test output (SRT), using bootstrapping simulations. Previous research indicated 0.70 dB as the typical within-subject SRT variability for normal-hearing adults. Study 2 showed that up to four triplets with decoding errors produce SRT variations within this range, suggesting that our proposed setup could be feasible for clinical applications.


Assuntos
Percepção da Fala , Adulto , Humanos , Teste do Limiar de Recepção da Fala , Audiometria da Fala , Ruído , Testes Auditivos
11.
Int J Audiol ; : 1-11, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38517324

RESUMO

OBJECTIVE: Knowledge regarding hearing acuity in the nonagenarian age group is sparse. In this study we aimed to advance our understanding of hearing loss in the 10th decade of life. DESIGN: A cross-sectional study in which standardised hearing measurements were performed during home visits, which included care home facilities and nursing homes to maximise participation. STUDY SAMPLE: Two unselected groups of individuals aged 90 (n = 42) and 95 (n = 49), sampled from the population-based Gothenburg H70 Birth Cohort Studies. RESULTS: 98% of the participants (95% CI [95, 100]) had some degree of hearing loss in their better ear, with 83% (95% CI [73, 89]) having a potentially disabling hearing loss of moderate degree or worse, according to WHO criteria. Furthermore, differences between the two age groups (five years apart) indicate an increasing hearing loss, primarily at frequencies ≥ 2 kHz. CONCLUSION: Hearing loss was present in almost all of the participants in the nonagenarian age group and among a majority of them potentially to a degree that would warrant rehabilitation. Carrying out standardised hearing measurements in a home setting was feasible in this age group and enhanced the representativeness of the study population.


Bilateral hearing loss affected almost all of the individuals in the nonagenarian age group with 8 in 10 having hearing loss of a degree severe enough to warrant intervention or hearing aid prescription.The findings provide valuable insight into hearing acuity among nonagenarians. Many earlier studies were limited to subjective hearing assessments, reviews of medical records and/or screening tests performed by non-audiologists.The final sample size was smaller than initially planned due to the COVID-19 pandemic. However, measures were taken to optimise the representativeness of the study sample.

12.
Artigo em Inglês | MEDLINE | ID: mdl-38530462

RESUMO

BACKGROUND: Otosclerosis is a primary osteodystrophy of the otic capsule that causes stapedo-vestibular ankylosis. Its diagnosis is suspected on the basis of clinical and audiometric elements, basically in the presence of conductive hearing loss with a normal eardrum. The CT-scan is an essential examination for the preoperative evaluation of otosclerosis. The aim of our study was to evaluate the use of CT-scanning in predicting the functional outcome of otosclerosis surgery by correlating postoperative audiometric results and preoperative CT findings. METHODS: We conducted a retrospective study at the ENT Department in association with the Medical Imaging Department of our hospital, over a period of 8 years, from January 2014 to December 2022 and involving 90 patients (104 ears). RESULTS: The average age of our patients was 40 years with extremes ranging from 22 to 61 years. We noted a sex ratio of 0.38. The preoperative CT-scan showed signs of otosclerosis in 87% of the cases and infra-radiological forms in 13% of the cases. Veillon stage II was the most frequent radiological stage encountered with a percentage of 48%. A good audiometric evolution, defined by a closure of postoperative Air Bone Gap (ABG ≤ 20 dB) and by an improvement of Bone Conduction (BC gain ≥ 0), was recorded in 86 cases (82.7%) for ABG and in 84 cases (80.8%) for BC gain. Scanographic predictive factors of poor postoperative outcome for ABG and BC gain were: advanced stages (Veillon stage III and IV), endosteal effraction, and round window involvement. According to multivariate analysis, only the extent of otosclerotic foci was directly and independently associated with the postoperative audiometric outcome. CONCLUSION: The CT-scan is an essential examination in the preoperative evaluation of otosclerosis. It allows a positive diagnosis to be made and evaluate the extension of otosclerosis. Moreover, thanks to the analysis of the extent of the otosclerosis foci, mainly by the Veillon classification, the CT-scan allows to predict the postoperative audiometric prognosis.

13.
Int J Prev Med ; 15: 2, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38487700

RESUMO

Background: Impact/impulse and continuous noise are two main causes of noise-induced hearing loss (NIHL) in workplaces. The aim of this study was to compare the effects of impulse/impact noise and continuous noise on hearing status. Methods: In this study, 259 workers referred to the occupational medicine clinic of Shahid Rahnemoun hospital, Yazd, Iran, entered the study and were divided into two groups: with exposure to impact/impulse noise and with exposure to continuous noise. Hearing thresholds were measured and compared between the two groups by pure-tone audiometry (PTA). The frequency of hearing loss and audiometric notch according to the results of PTA was compared between the two groups. Data were analyzed by SPSS (ver. 16) using Student's t-test, Chi-square test, and Mann-Whitney U test. Results: Hearing thresholds were significantly higher at all frequencies in the impact noise group. The hearing threshold at 6000 Hz was higher than other frequencies in both groups. The frequency of hearing loss at high frequencies was higher in the impact group. The frequency of audiometric notch was not significantly different between the two groups. Conclusions: The results of this study showed that hearing loss after exposure to impact/impulse noise is probably more frequent and more severe than exposure to continuous noise, but the pattern of hearing loss is similar in both types of noise exposure.

14.
Int J Audiol ; : 1-10, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551077

RESUMO

OBJECTIVE: To explore the feasibility of remote diagnostic hearing testing within schools, for school-entry aged children (4-7 years). DESIGN: A prospective cross-sectional comparative study design was used to establish the reliability of remote hearing assessment by comparing traditional face-to-face pure tone audiometry (PTA) with remote PTA, traditional otoscopy with remote video otoscopy and interpretation of tympanograms in-person with remote analysis. STUDY SAMPLE: 464 school-entry year level children from 18 schools. RESULTS: Air conduction thresholds established by remote testing were within a clinically acceptable range of ±10 dB HL from traditional thresholds in 98% of cases at 1 kHz and 97.8% at 4 kHz. Bone conduction thresholds varied by ≤10 dB HL in 100% of cases at 1 kHz and 95.7% at 4 kHz. Remote otoscopy and tympanometry interpretation had 78.6% agreement (moderate; κ = 0.6) and 92.2% agreement (almost perfect; κ = 0.9), respectively. CONCLUSIONS: We found there to be good reliability between face-to-face PTA and remote PTA performed within the school environment. Furthermore, assessment of the outer and middle ear via video otoscopy and remote tympanometry classification were both viable. Remote diagnostic hearing tests in schools can extend reach of paediatric services in rural areas.

15.
Toxics ; 12(3)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38535923

RESUMO

Hearing loss (HL) is associated with poorer language development and school performance. Ototoxic substances such as metals and solvents, including benzene, are a risk factor associated with HL. This study examines potential associations between the benzene metabolite trans,trans-muconic acid (t,t-MA) and HL in youth of the National Health and Nutrition Examination Survey (NHANES). Logistic regression calculated adjusted odds ratio (aOR) associations between HL and urinary t,t-MA quartiles, natural-log transformed, and doubled urinary t,t-MA. Hearing threshold pure-tone average (PTA) at speech frequencies (SF) 0.5, 1, 2, and 4 kHz and high frequencies (HF) 3, 4, and 6 kHz were analyzed for slight HL (PTA > 15 dB) and mild HL (PTA > 20 dB). Urinary t,t-MA was statistically significantly associated with both slight SF and HF HL. For each doubling of t,t-MA there were increased odds of having slight SFHL (aOR = 1.42; 95% CI: 1.05, 1.92), slight HFHL (aOR = 1.31; 95% CI: 1.03, 1.66), mild SFHL (aOR = 1.60; 95% CI: 1.10, 2.32), and mild HFHL (aOR = 1.45; 95% CI: 1.03, 2.04). To our knowledge, this is the first population-based report of an association between SFHL, HFHL, and the benzene metabolite t,t-MA in youth 6 to 19 years old.

16.
J Laryngol Otol ; : 1-7, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38456283

RESUMO

OBJECTIVE: This study aimed to compare the peripheral-to-central auditory systems of people with coronavirus disease 2019 to a well-matched control group and examine the long-term effects of coronavirus disease 2019 on the auditory system. METHOD: Participants who were outpatients of coronavirus disease 2019 (n = 30) were compared with a well-matched control group (n = 30). Behavioural and electrophysiological tests were performed, and tests were repeated at six months in the coronavirus disease 2019 group. RESULTS: Statistically significant differences were observed in the right ear at 10 kHz (p = 0.007) and 12.5 kHz (p = 0.028), and in the left ear at 10 kHz (p = 0.040) and 12.5 kHz (p = 0.040) between groups. The groups had no difference regarding the other audiological test results (p > 0.05). CONCLUSION: Extended high-frequency thresholds were affected in the coronavirus disease 2019 patients. No other findings indicated that the peripheral-to-central auditory system was affected. The effect on extended high-frequency thresholds appeared permanent, but no clinically significant new, late-onset auditory system effects were observed.

17.
Environ Sci Pollut Res Int ; 31(16): 24129-24138, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38436861

RESUMO

The study aimed to evaluate the impact of occupational noise on hearing loss among healthcare workers using audiometry. A longitudinal study was conducted with a six-month follow-up period in a hospital with 21 participants, divided into high-noise-exposure (HNE) and low-noise-exposure (LNE) groups. Mean noise levels were higher in the HNE group (70.4 ± 4.5 dBA), and hearing loss was measured using pure-tone audiometry at baseline and follow-up. The HNE group had significantly higher mean threshold levels at frequencies of 0.25 kHz, 0.5 kHz, 4.0 kHz, and an average of 0.5, 1, 2, and 4 kHz (all p-values < 0.05) after the follow-up period. After adjusting for confounding factors, the HNE group had significantly higher hearing loss levels at 0.25 kHz, 0.5 kHz, and average frequencies of 0.5, 1, 2, and 4 kHz compared to the LNE group at the second measurement. Occupational noise levels above 65 dBA over six months were found to cause significant threshold changes at frequencies of 0.25 kHz, 0.5 kHz, and an average of 0.5-4.0 kHz. This study highlights the risk of noise-induced hearing loss among healthcare workers and emphasizes the importance of implementing effective hearing conservation programs in the workplace. Regular monitoring and assessment of noise levels and hearing ability, along with proper use of personal protective equipment, are crucial steps in mitigating the impact of occupational noise exposure on the hearing health of healthcare workers.


Assuntos
Perda Auditiva Provocada por Ruído , Ruído Ocupacional , Doenças Profissionais , Exposição Ocupacional , Humanos , Estudos Longitudinais , Ruído Ocupacional/efeitos adversos , Perda Auditiva Provocada por Ruído/epidemiologia , Recursos Humanos em Hospital , Audição
18.
Indian J Otolaryngol Head Neck Surg ; 76(1): 899-903, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38440432

RESUMO

During the initial phase of the COVID-19 pandemic, there was ongoing investigation into potentially effective treatments. Antiviral medications such as Favipiravir and Hydroxychloroquine were employed to treat COVID-19 infections. However, limited studies have examined the adverse effects of these medications on hearing, particularly at extended high frequencies. This study included 10 subjects who had received medications like Azithromycin, a combination of Favipiravir and Hydroxychloroquine, and Hydroxychloroquine alone as part of their COVID-19 treatment. These subjects had previously undergone extended high-frequency audiometry testing (from 8 to 20 kHz) as part of another project conducted by the same department before contracting COVID-19. Post-COVID-19 extended high-frequency audiometry was performed 1 month after the patients received a negative RT-PCR report. The results were then compared using a Paired t-test. A significant shift in the thresholds of high frequencies above 8-20 kHz is found in subjects who had received Favipiravir and Hydroxychloroquine medications. We observed a significant impact of COVID-19 medications on high-frequency hearing, which tends to go unnoticed in regular pure-tone audiometry evaluations. Therefore, our study emphasizes the need for regular follow-ups, including detailed audiological assessments that incorporate extended high-frequency testing, at least once every 3 months for patients who have taken medications for COVID-19 treatment.

19.
Indian J Otolaryngol Head Neck Surg ; 76(1): 176-180, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38440464

RESUMO

Senile deafness and hearing loss in adults over 50 are major public health issues as a result of the population's ageing demographic. Menopausal women tend to develop hearing loss, while no clear link has been found between the two. The purpose of this study was to determine how menopause and diabetes mellitus affects hearing loss. We assessed 158 menopausal women in total. Pure Tone Audiometry and HbA1c levels was measured, along with appropriate clinical history and examination. The association between those levels and hearing was researched by chi-square test. There were 158 study participants. Mean age of the study population was 50.5 (± 2.49) years. Onset and duration of hard of hearing was assessed in 41 patients (25.9%). 33% (N = 53) of the patients had history of Diabetes mellitus, of which 52.8% offered history of the disease for more than or equal to five years. On audiological assessment, 74.1% had no hearing loss (N = 117), 4.4% had unilateral sensorineural hearing loss (N = 7) and 21.5% had bilateral sensorineural hearing loss (N = 34). Statistics show that hearing loss is statistically connected with ageing and poor glycemic management. With chi square values of 9.629 and P value 0.002 found a significant correlation between ageing and hearing loss. Poor glycemic control is significantly associated with hearing loss with a chi-square value of 4.304 and P value 0.038. Poor glycemic control and menopause is found to be strongly associated with sensorineural hearing loss. Further prospective, hormonal studies including larger population is recommended.

20.
Indian J Otolaryngol Head Neck Surg ; 76(1): 36-40, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38440463

RESUMO

A type-I hypersensitivity reaction of the nasal mucosa, allergic rhinitis (AR) is distinguished by nasal obstruction, watery rhinorrhea, sneezing, and throat, mouth, and nose irritation. It is assumed that allergies can affect the inner, middle, or outer ear. Many writers have studied the relationship between allergic rhinitis and otitis media. Most of them concur that bacterial infection and Eustachian tube obstruction are significant risk factors for the development of otitis media with effusion in addition to allergies. One hundred study participants had a full clinical evaluation that included an ENT history and examination. In the ENT OPD, the audiological examination was conducted using Pure Tone Audiometry (PTA) and Impedance Audiometry (IA). At frequencies of 250 and 8000 Hz, respectively, the bone and air conduction thresholds were studied. The commercially available "AT235 INTERACOUSTICS" tympanometer was used for the tympanometry procedure. With pressure variations between + 200 and - 300daPa, tympanometry was carried out employing a 226 Hz probe tone. Mean age of study population was 52.16 and 24% each in age group 51 to 60 and 61 to 70 years respectively. 73 (73%) were male and 27 (27%) were female. 46% of allergic rhinitis study population was found to have normal hearing and 43% had mild conductive hearing loss. Most common type of impedance curve was A type (47%). Patients having acute phase of allergy with symptoms less than 3 months had more ear block and secretory otitis media. Patients with duration more than 3 months had resolved secretory otitis media hence the hearing was normal in 33 cases and 11 had mild conductive hearing loss. This study was concluded that there is correlation between the severity of the hearing loss and duration of allergic rhinitis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...